Which cable and breaker to use
Back

Which cable and breaker to use

Put in the appliance power, the voltage and the distance from the consumer unit. You get the cable size and the breaker, following the wiring regulations.

The appliance
The circuit is for
Copper cable (size)
4 mm² with a 32 A breaker

5,500 W at 230 V draws 23.9 A. The breaker has at least 10% headroom and the cable carries 32 A, with a 0.9% voltage drop over 10 m.

32 Abreaker
23.9 Aappliance current

Also check the appliance manual: it gives the cable and breaker the manufacturer asks for. Showers, electric taps and bathroom sockets need 30 mA RCD protection on the circuit (wiring regulations).

What to charge for the new circuit
€295 for labour, the most common rate in Ireland (€210 to €780 each).
How we work it out

Current = power ÷ voltage. Breaker = the first standard size with at least 10% headroom over the current (an appliance left on for a long time won't trip for no reason). Cable = the smallest that carries the breaker's current (copper with PVC insulation, in conduit in the wall, 2 loaded conductors, per the wiring regulations' current-carrying tables) and keeps the voltage drop to 4% or less there and back. Minimum 2.5 mm² for sockets and appliances and 1.5 mm² for lighting.